Applies to: MIRA 7
How to remove the exhaust fan from a MIRA 7.
Warning: Turn the machine off and unplug it before you start.
What you need
- Phillips screwdriver
- Cabinet key
- Allen key set
Remove the fan
-
Use the cabinet key to open the lower left panel on the back of the machine.

-
Reach over the fan and unscrew the four bolts that hold it to the cabinet floor.

-
Find, by feel, the clamp at the back of the machine that secures the duct hose. With a Phillips head screwdriver, loosen the duct hose clamps and remove the hose from the back of the machine.

-
Carefully cut the zip ties that hold the capacitor to the bottom of the machine, and the zip ties that hold the wires together.

-
Open the lower panel on the right side of the machine with the cabinet key.

Follow the two wires from the fan to the lever DIN connectors. Flip up the orange levers to release the wires, and gently pull the wires out of the connectors.
-
Follow the green and yellow ground wire from the fan to the ground bar. With a Phillips head screwdriver, disconnect the ground wire from the ground bar.

Lift the fan up and out of the cabinet.
Need a hand?
Email support@aeonlaser.us or call 321-260-2325. More ways to reach us are on the Support page.