Removing the Fan: MIRA 9

Updated November 12, 2026

Applies to: MIRA 9

How to remove the exhaust fan from a MIRA 9.

Warning: Turn the machine off and unplug it before you start.

What you need

  • Phillips screwdriver
  • Cabinet key
  • Allen key set

Remove the fan

  1. Use the cabinet key to open the lower right panel on the back of the machine.

    Lower right panel on the back of the MIRA 9
  2. With a Phillips head screwdriver, loosen the duct hose clamps and remove the hose from the fan and from the back of the machine.

    Duct hose clamps on the fan hose
  3. Unscrew the four bolts that hold the fan to the cabinet floor.

    Fan bolted to the cabinet floor
  4. Follow the two wires marked “Fan” to the lever DIN connectors. Flip up the orange lever to release each wire, and gently pull the wire out of the connector.

    Fan wires at the lever DIN connectors
    Orange lever flipped up on a lever DIN connector
  5. Follow the green and yellow ground wire from the fan to the ground bar. With a Phillips head screwdriver, disconnect the ground wire from the ground bar.

    Green and yellow ground wire on the ground bar
  6. Lift the fan up and out of the cabinet.

    Fan removed from the cabinet

Need a hand?

Email support@aeonlaser.us or call 321-260-2325. More ways to reach us are on the Support page.