Removing the Internal Chiller: MIRA 7

Updated November 12, 2026

Applies to: MIRA 7

How to remove the internal chiller from a MIRA 7. To prevent water damage, remove the chiller before you turn the machine on its side to move it through stairways, hallways and doorways.

Internal chiller of the MIRA 7
The internal chiller

Warning: Turn the machine off and unplug it before you start.

Caution: Drain the chiller completely before you remove it.

What you need

  • Phillips head screwdriver
  • Masking tape
  • Towel
  • Wire cutters or scissors
  • Bucket

Remove the chiller

  1. Using a Phillips head screwdriver, remove the 4 screws on the bottom left panel at the back of the machine to open the exhaust system access panel.

    Four screws on the bottom left panel at the back of the laser
    Bottom left panel open at the back of the laser
  2. Find the side of the chiller, with its power plug, signal wire and the 2 silicone hoses that connect to the chiller inlet and outlet.

    Power plug, signal wire and 2 silicone hoses on the chiller
  3. Unplug the power plug from the chiller by gently pulling it out. Remove the signal wire by unscrewing its retaining ring and then pulling it out.

  4. Wrap a piece of masking tape around one of the hoses, and put a second piece of tape on the side of the chiller where that hose connects. This marks which fitting the hose belongs to, so both hoses are reconnected correctly.

    Masking tape on one hose and on the side of the chiller
  5. Using small wire cutters, clip the zip ties that secure the hoses to the chiller. Do this at the chiller end of the hoses, not the machine end.

  6. Gently pull the hoses off the chiller inlet and outlet, with a towel or bucket ready to catch any water.

    Hoses removed from the chiller inlet and outlet
  7. Remove the 4 Phillips head screws that hold the chiller in the machine, one at each corner of the rear panel of the chiller.

    Four screws that hold the chiller in the machine
  8. Gently slide the chiller out of the machine. Use the open side panel to guide it carefully out of the back.

    Chiller sliding out of the machine

Need a hand?

Email support@aeonlaser.us or call 321-260-2325. More ways to reach us are on the Support page.

← Back to the Knowledge Base