Applies to: MIRA
How to replace the 24V power supply in a MIRA.
Warning: Turn the machine off and unplug it before you start.
What you need
- Cabinet key
- Allen wrench
- Phillips head screwdriver
- New 24V power supply
Replace the power supply
-
Open the lower left side panel with the cabinet key, and find the 24V power supply.

-
Take a picture of the wiring connections on the 24V power supply, to refer to when you reinstall.

-
Use a Phillips head screwdriver to loosen the wire terminals, and remove the wires.

-
Use an Allen wrench to remove the mounting bolts in the lower left corner and the top right corner, and remove the unit.

-
Before you install the new unit, look through its grate and check that the internal voltage switch is set to “115V”.

-
Mount the new unit with the bolts in the lower left corner and the top right corner, using the Allen wrench.

-
Attach the wires to the new unit, following your photo from step 2. Tighten the screws at the wire terminals with a Phillips head screwdriver.

Close the panel and lock it with the cabinet key.